+8615966019173
Thermal Instrument Calibrator
Home - Products - Dry Block Temperature Calibrator - Thermal Instrument Calibrator - DY-CTRE100 Intelligent Dry Block Instrument
The intelligent dry block instrument can simultaneously collect 3 standard platinum resistance thermometers (Pt25) or 1 standard thermocouple thermometer and 5 Support the temperature value, resistance value and fluctuation curve of the temperature sensor under inspection. The channel collection method is inspection, and the channel can also be switched manually. The device can switch between resistance mode and galvanic mode.
DY-CTRE100 Intelligent Dry Block Instrument is designed by the company for calibrating temperature sensors of various low, medium and high temperature dry block temperature calibrators.
The equipment can be matched with dry body furnace, standard sensor, ready to check the sensor, equipped with a small upper computer settings can be realized, real-time control of the dry body furnace temperature settings, the standard to be checked, the current temperature value of the sensor to be checked, resistance value, volatility curve.
Typical applications of intelligent dry block instrument :
•Shipbuilding
•Pharmaceutical industry
•Industrial (laboratory, workshop, production line)
•Manufacturers of temperature sensors and temperature transmitters
•Calibration service companies and calibration service industry
•For on-site measurement and calibration work
Each unit includes: Accredited report of calibration, insert, insert removal tool, power cord, usermanual
Recommended accessories:Dry block temperature calibrator
1. Equipment can be equipped with dry body furnace, standard sensors, ready to check the sensor, equipped with a small host computer settings can be realized, real-time control of the dry body furnace temperature settings, the standard being checked, the current temperature value of the sensor being checked, the resistance value, volatility curve.
2. The device has several independent standard channels for measuring standard platinum resistance (Pt25), standard thermocouples;
3.The equipment has a number of inspected channels, for testing industrial PT100, 8 kinds of thermocouples K, E, J, T, B, N, R, S;
4. Channel optional, according to their own requirements to choose a single channel or multiple channels. You can manually switch channels or patrol mode;
5. The device is divided into two modes - resistance mode and galvanic coupling mode.
Model | DY-CTRE100 |
Collection Accuracy | 0.02% |
Adaptation Sensor | ①Industrial four-wire Pt100 thermal resistance sensor ②Industrial thermocouple sensors, K, E, J, T, B, N, R, S ③Standard platinum resistance thermometer ④Standard thermocouple thermometer |
Mode Switchable | Thermal resistance mode: 3 standard platinum resistors (Pt25) + 5 PT100 Thermocouple mode: 1 standard thermocouple + 5 thermocouples (gradient numbers can be different) |
Product Features | ①Data recording and query functions, the recording time interval can be set ②The channel has temperature display, resistance display, 3-minute and 10-minute fluctuation display ③Each channel has a deviation correction function to facilitate internal deviation correction ④ 3 standard channels, 1-3 can measure standard platinum resistance thermometers, and channel 3 can also measure standard thermocouples. ⑤Curve display, can display the temperature range automatically or manually. ⑥5 inspection channels, which can simultaneously detect Pt100 thermal resistance sensors or industrial thermocouple sensors, K, E, J, T, B, N, R, S (thermocouples can be mixed) |
Equipment Type | Device Nam | Temperature Range |
Thermostatic Equipment | Dry block temperature calibrator | -100℃-40℃,-30℃-1200℃ |
Intelligent Dry Block Instrument | Adaptation Sensor | ①Industrial four-wire Pt100 thermal resistance sensor ②Industrial thermocouple sensors, K, E, J, T, B, N, R, S ③Standard platinum resistance thermometer ④Standard thermocouple thermometer |
Standardizer | Standard Platinum Resistor | First-class and second-class standard platinum resistors, temperature range (℃): -189.342℃~419.527℃ |
Standard Thermocoupl | First-class and second-class standard thermocouples, temperature range (℃): 0℃~1300℃/1100℃~1500℃ | |
Temperature Sensors | Thermal Resistance Sensor | Industrial four-wire Pt100 thermal resistance senso |
Thermocouple Sensor | Industrial thermocouple sensors, K, E, J, T, B, N, R, S | |
Equipment Matching | Host, USB expansion port, wireless mouse, charger, 8 adapter cables, instrument carrying case |